2026/10/09 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:01:173
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2026/10/08 0.5806 1.02466 0.7580 00.6682 00.0000 00.0000 95.5766 02.7980 00.1718 00.0095 00.0104 00.0000 00.0025 00.0016 00.0013 00.0010 00.0005 00.0000
CUSTER ST @ LINE AD ST1 2026/10/08 0.5920 1.04108 0.7276 00.8093 00.0000 00.0000 93.2208 04.9721 00.2612 00.0046 00.0040 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2026/10/08 0.5922 1.03457 0.8932 00.9619 00.0000 00.0000 93.2842 04.6703 00.1653 00.0065 00.0097 00.0000 00.0020 00.0014 00.0023 00.0017 00.0008 00.0000
CHANDLER ST DISCHARGE G 2026/10/08 0.5903 1.03360 0.8474 00.9088 00.0000 00.0000 93.6401 04.4050 00.1754 00.0077 00.0092 00.0000 00.0019 00.0014 00.0012 00.0009 00.0004 00.0000
FM 63 - Columbia GC @ 2 2026/10/08 0.6035 1.07924 0.1954 00.4111 00.0000 00.0000 90.6265 08.3620 00.3364 00.0227 00.0299 00.0000 00.0061 00.0040 00.0025 00.0018 00.0009 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.